rs148629782
Variant summary
Our verdict is Benign. Variant got -15 ACMG points: 1P and 16B. PP2BP4_StrongBP6_Very_StrongBS2
The NM_006206.6(PDGFRA):āc.3228C>Gā(p.Ile1076Met) variant causes a missense change involving the alteration of a non-conserved nucleotide. The variant allele was found at a frequency of 0.000123 in 1,613,870 control chromosomes in the GnomAD database, including 2 homozygotes. In-silico tool predicts a benign outcome for this variant. 15/21 in silico tools predict a benign outcome for this variant. Variant has been reported in ClinVar as Likely benign (ā ā ).
Frequency
Consequence
NM_006206.6 missense
Scores
Clinical Significance
Conservation
Genome browser will be placed here
ACMG classification
Verdict is Benign. Variant got -15 ACMG points.
Transcripts
RefSeq
Gene | Transcript | HGVSc | HGVSp | Effect | #exon/exons | MANE | Protein | UniProt |
---|---|---|---|---|---|---|---|---|
PDGFRA | NM_006206.6 | c.3228C>G | p.Ile1076Met | missense_variant | 23/23 | ENST00000257290.10 | NP_006197.1 |
Ensembl
Gene | Transcript | HGVSc | HGVSp | Effect | #exon/exons | TSL | MANE | Protein | Appris | UniProt |
---|---|---|---|---|---|---|---|---|---|---|
PDGFRA | ENST00000257290.10 | c.3228C>G | p.Ile1076Met | missense_variant | 23/23 | 1 | NM_006206.6 | ENSP00000257290.5 | ||
ENSG00000282278 | ENST00000507166.5 | c.2508C>G | p.Ile836Met | missense_variant | 24/24 | 2 | ENSP00000423325.1 |
Frequencies
GnomAD3 genomes AF: 0.0000920 AC: 14AN: 152150Hom.: 0 Cov.: 33
GnomAD3 exomes AF: 0.000251 AC: 63AN: 251238Hom.: 1 AF XY: 0.000324 AC XY: 44AN XY: 135774
GnomAD4 exome AF: 0.000126 AC: 184AN: 1461602Hom.: 2 Cov.: 35 AF XY: 0.000184 AC XY: 134AN XY: 727146
GnomAD4 genome AF: 0.0000919 AC: 14AN: 152268Hom.: 0 Cov.: 33 AF XY: 0.000148 AC XY: 11AN XY: 74448
ClinVar
Submissions by phenotype
Gastrointestinal stromal tumor Benign:2
Likely benign, criteria provided, single submitter | clinical testing | Labcorp Genetics (formerly Invitae), Labcorp | Jan 27, 2024 | - - |
Likely benign, criteria provided, single submitter | clinical testing | Illumina Laboratory Services, Illumina | Jan 12, 2018 | This variant was observed in the ICSL laboratory as part of a predisposition screen in an ostensibly healthy population. It had not been previously curated by ICSL or reported in the Human Gene Mutation Database (HGMD: prior to June 1st, 2018), and was therefore a candidate for classification through an automated scoring system. Utilizing variant allele frequency, disease prevalence and penetrance estimates, and inheritance mode, an automated score was calculated to assess if this variant is too frequent to cause the disease. Based on the score and internal cut-off values, a variant classified as likely benign is not then subjected to further curation. The score for this variant resulted in a classification of likely benign for this disease. - |
Idiopathic hypereosinophilic syndrome Benign:1
Benign, criteria provided, single submitter | clinical testing | Illumina Laboratory Services, Illumina | Jan 12, 2018 | This variant was observed in the ICSL laboratory as part of a predisposition screen in an ostensibly healthy population. It had not been previously curated by ICSL or reported in the Human Gene Mutation Database (HGMD: prior to June 1st, 2018), and was therefore a candidate for classification through an automated scoring system. Utilizing variant allele frequency, disease prevalence and penetrance estimates, and inheritance mode, an automated score was calculated to assess if this variant is too frequent to cause the disease. Based on the score and internal cut-off values, a variant classified as benign is not then subjected to further curation. The score for this variant resulted in a classification of benign for this disease. - |
Hereditary cancer-predisposing syndrome Benign:1
Likely benign, criteria provided, single submitter | clinical testing | Ambry Genetics | Jul 22, 2019 | This alteration is classified as likely benign based on a combination of the following: seen in unaffected individuals, population frequency, intact protein function, lack of segregation with disease, co-occurrence, RNA analysis, in silico models, amino acid conservation, lack of disease association in case-control studies, and/or the mechanism of disease or impacted region is inconsistent with a known cause of pathogenicity. - |
Computational scores
Source:
Splicing
Find out detailed SpliceAI scores and Pangolin per-transcript scores at